Fluid Condition Monitoring
Oil & Fluid Testing Services
Comprehensive physical and chemical testing to assess lubricant condition, detect degradation, and prevent costly equipment failures before they happen.
Beyond Elemental Analysis
While ICP spectroscopy tells you what's in your oil, physical and chemical tests tell you how the oil itself is performing. Viscosity, oxidation, acid number, and particle count together paint a complete picture of lubricant health and remaining useful life.
Our testing follows current ASTM methods, and our analysts communicate findings in plain language — not just raw data. We help you decide whether to change the oil, extend the drain interval, or investigate a developing problem.
We follow current ASTM methods and communicate findings in plain language — not just raw data.
Also see ICP SpectroscopyTests We Perform
Viscosity
ASTM D445Measures the oil's resistance to flow at 40°C and 100°C. Viscosity outside the specified range indicates shear degradation, contamination, or wrong-grade oil — all of which accelerate wear.
Why it matters: The single most important lubricant property. Wrong viscosity = wrong film thickness = accelerated wear.
Oxidation / Nitration
ASTM E2412 (FTIR)Infrared spectroscopy quantifies oxidation and nitration by-products that form as oil ages under heat and combustion gases. High oxidation leads to varnish, sludge, and acid formation.
Why it matters: Catches oil degradation early — before it deposits varnish on critical surfaces or attacks seals.
Total Acid Number (TAN)
ASTM D664Measures the concentration of acidic compounds in the oil. Rising TAN indicates oxidative degradation and depletion of alkaline additives, increasing corrosion risk.
Why it matters: Critical for turbine oils, compressor oils, and any system where acid corrosion is a concern.
Total Base Number (TBN)
ASTM D2896Measures the alkaline reserve remaining in engine oils to neutralize combustion acids. When TBN drops below a threshold, the oil can no longer protect against acid corrosion.
Why it matters: The primary indicator for engine oil drain intervals in diesel and gas engines.
Particle Count
ISO 4406Counts and sizes solid particles per milliliter of fluid. Reported as an ISO cleanliness code. Essential for hydraulic systems, turbines, and precision gearboxes where cleanliness is critical.
Why it matters: Even sub-micron particles cause three-body abrasive wear in tight-clearance components.
Water Content
ASTM D6304 (Karl Fischer)Precisely measures free, emulsified, and dissolved water in oil. Water promotes corrosion, reduces film strength, and accelerates additive depletion.
Why it matters: Even 0.1% water can reduce bearing fatigue life by 50% or more.
Fuel Dilution
ASTM D3524Detects and quantifies diesel fuel contamination in engine crankcase oil. Fuel dilution thins the oil, reduces viscosity, and strips protective additives.
Why it matters: Indicates injector problems, ring wear, or extended idling — all requiring immediate attention.
Coolant / Glycol
ASTM D2982Detects ethylene or propylene glycol from coolant leaks into the engine oil or gearbox. Glycol contamination causes rapid bearing corrosion and oil thickening.
Why it matters: A small coolant leak undetected for one oil change interval can destroy an engine.
Pricing & Turnaround
Tests can be ordered individually or as part of a bundled panel. Volume discounts available for fleets and industrial facilities.
Basic Condition Panel
Viscosity, oxidation (FTIR), TAN or TBN, and water content. Ideal for routine oil condition monitoring.
Get a quoteFull Condition Panel
All basic tests plus particle count, fuel dilution, and coolant check. Comprehensive snapshot of oil and system health.
Get a quoteCustom Test Selection
Pick only the tests relevant to your equipment type and application. Contact us to build a custom panel.
Get a quoteNot Sure Which Tests You Need?
Tell us your equipment type and operating conditions — we'll recommend the right test package.